K35D2 series 3 position 5 way double electrical control valve
Introduction:
This series of valves is composed of two normally open solenoid pilot valves and one main valve.It is mainly used as a control element for actuators such as cylinders and other occasions with intermediate pause state. According to the different relationship between the chambers when the valve core is in the middle position, it is divided into three structures: medium pressure, middle discharge and middle seal.
Working pinciple:
When a pilot valve receives an electrical signal, the pressure in the control chamber at the corresponding end of the main valve is relieved, and the valve is reversed; After the electric signal is eliminated, the valve core automatically resets to the middle position.
Available model:
K35D2-6 K35D2-8 K35D2-10 K35D2-15 K35D2-20 K35D2-25
K35D2-6P K35D2-8P K35D2-I0P K35D2-15P K35D2-20P K35D2-25P
K35D2-6Y K35D2-8Y K35D2-10Y K35D2-15Y K35D2-20Y K35D2-25Y
Specification:
model | K35D2-6 | K35D2-8 | K35D2-10 | K35D2-15 | K35D2-20 | K35D2-25 | |
K35D2-6P | K35D2-8P | K35D2-I0P | K35D2-15P | K35D2-20P | K35D2-25P | ||
K35D2-6Y | K35D2-8Y | K35D2-10Y | K35D2-15Y | K35D2-20Y | K35D2-25Y | ||
DN(mm) | 6 | 8 | 10 | 15 | 20 | 25 | |
working medium | compressed air | ||||||
working pressure(MPa) | 0.2-0. 8 | ||||||
voltage(V) | AC:220;36 DC::24;12 | ||||||
voltage fluctuation(%) | ♦10〜--15 | ||||||
reversing time≤(S) | 0.06 | 0.08 | 0.12 | ||||
reversing frequency≥(Hz) | 8 | 6 | 4 | ||||
leakage(≤ cm3/min) | 10 | 25 | 50 | ||||
effective area≥(mm2) | 10 | 20 | 40 | 60 | 110 | 190 | |
medium temperatur(℃) | 5〜50 | ||||||
ambient temperature(℃) | 5〜50 | ||||||
Min working frequency(times / day) | 1/30 | ||||||
solenoid pilot valve DN(m) | 1.2 | 2 | 3 | ||||
power consumption(w) | AC | 12 | 15 | 28 | |||
DC | 6 | 8 | 10 | ||||
Durability (ten thousand times) | 150 |