Hammer Union Pressure Transmitter
Hammer Union Pressure Transmitter
Collection
Hammer Union Pressure Transmitter
Collection
***
  • Detail
  • Parameters
  • Review

Hammer Union fitting for use in oil well cementing, fracturing and acidizing

Features & Benefits

  • FM, CSA and ATEX Intrinsically Safe

  • Hammer Union pressure fitting

  • Shock and vibration resistant

  • Eight gage sensor design

  • Pressure up to 20,000 PSI (1379 bar)

Description

Completed interchangeable with Viatran Model 510 pressure transmitters are equipped with a Hammer Union fitting for use in oil

well cementing, fracturing and acidizing. They have been designed to be accurate yet rugged instruments ideally suited to the harsh oil field environment.



Pressure Connection 510 ..........................................................Male hammer union 2 inch #1502

Pressure Cavity Volume ..............................<0.78 cubic inches

Proof Pressure ...........................................1.67 times FSPR or 22.5K PSI (1550 bar)

Burst Pressure ...........................................3 times the FSPR, limited by union #1502: 22.5K PSI (1550 bar)

Shock Limitation ..........................................100 G’s

Weight ........................................................5.5 lbs nominal (2.4 kg)

Enclosure Materials .....................................304 stainless steel

Wetted Materials .........................................Inconel X-750, heat treated per NACE MR0175-2000

Identification ................................................Laser etched onto body

Enclosure Classification ...............................NEMA 4X