K25D series two position five way solenoid directional valve
Introduction:
The two position five way electric control slide valve is a soft sealed sliding column directional valve. This series valve has the advantages of good sealing performance, low starting pressure, reliable performance and long durability. It is often used as the control element of double acting cylinder. Dual electric control valve has memory function. Because this series of valves only need pulse electric signal, it can prolong the durability of electromagnetic components.
Available model:
K25D-6 K25D-8 K25D-10 K25D-I5 K25D-20 K25D-25 K25D-32 K25D-40
K25D2-6 K25D2-8 K25D2-10 K25D2-15 K25D2-20 K25D2-25 K25D2-32 K25D2-40
Technical parameters:
model | K25D-6 | K25D-8 | K25D-10 | K25D-15 | K25D-20 | K25D-25 | K25D-32 | K25D-40 | |
K25D2-6 | K25D2-8 | K25D2-10 | K25D2-15 | K25D2-20 | K25D2-25 | K25D2- 32 | K25D2-40 | ||
DN(mm) | 6 | 8 | 10 | 15 | 20 | 25 | 32 | 40 | |
working medium | compressed air | ||||||||
working pressure(MPa) | 0.2 ~0.8 | ||||||||
voltage(V) | AC: 220; 36;other DC:24; 12;other | ||||||||
voltage fluctuation<%) | + 10〜-15 | ||||||||
reversing time(s) | 0.06 | 0.08 | 0.12 | 0.2 | |||||
reversing frequency≥(Hz) | 8 | 6 | 4 | 2 | |||||
effective area≥(mm2) | 10 | 20 | 40 | 60 | 110 | 190 | 300 | 400 | |
leakage≤(cm3/min) | 50 | 100 | 200 | 300 | |||||
medium temperatur(℃) | 5-50 | ||||||||
ambient temperature(℃) | 5〜50 | ||||||||
Min working frequency(times / day) | 1/30 | ||||||||
solenoid pilot valve DN(mm) | 1.2 | 2 | 3 | ||||||
power consumption(w) | AC | 12 | 15 | 28 | |||||
DC | 6 | 8 | 10 | ||||||
Durability (ten thousand times) | 150 |